TSC 70 Open

1st image of the TSC 70 Open
2nd image of the TSC 70 Open
1st image of the TSC 70 Open
2nd image of the TSC 70 Open
This article is currently unavailable!
Product Description
An open measuring cell intended for investigating liquid electrolytes.
This measuring cell has a 70 µL platinum crucible as sample container. For larger sample volumina, please use the TSC 1600 Open cell.
Since the cell is open to atmosphere, only non-volatile, non-air- or moisture-sensitive samples can be readily measured.
Product Details
Article No.:
840201
Material:
Gold-plated base (thermo block), platinum crucible
Thermosensor:
Pt100 (in thermo block)
Working Electrode:
Electrode plug with 4 separate Pt-wires sealed in glass
Sample Volume:
100 µL (max.)
×
Detailed Description
The measuring cell TSC 70 Open consists of the following parts:
  • 1 gold-plated thermo block with integrated Pt100 sensor
  • 1 platinum crucible (Vmax = 100 µL, Vmin = 70 µL)
  • 1 electrode plug with four separately connectable platinum electrodes (0.25 mm diameter each with a polished front end, insulated by lime-soda glass)
To use this measuring cell, either a Microcell HC Open or the extension set including a positioning unit for the Microcell HC Closed is required.
Technical Details
  • Vmax = 100 µL, Vmin = 70 µL
  • Cell materials: platinum crucible (sample container, electrodes), gold-plated copper with nickel interlayer
  • USB plug with integrated Pt100 sensor inside measuring cell
  • Comes with electrode plug: 4 platinum wires of 0.25 mm diameter surrounded by lime-soda glass, front-end mirror-like polished
  • Temperature range (operation): -40 °C to +100 °C depending on sample amount and dew point
  • Temperature range (storage): +10 °C to +30 °C
Suitable other Products
The measuring cell TSC 70 Open is compatible with the following products:
The measuring cell TSC 70 Open has for instance been used for the following applications:
  • Conductivity measurements of ionic liquids and mixtures of lithium salts with glymes by impedance spectroscopy
  • Determination of stability windows of ionic liquids by cyclic voltammetry
The low sample volume is the big advantage in case of both applications. The low vapor pressure of these samples allows for measurements inside a glovebox.
Please also visit the Literature section for a list of pulications.